1. Scope of Application
GTT-84X series digital transformer protection measurement and control device, mainly applies to 110kV and the following various voltage levels two / three coil transformer protection device. GTT-84(2) X series device includes: GTT-84(2)1 differential protection device, GTT-84(2)2 high backup protection measurement and control device is composed of transformer protection system.
2. Main Protection Function
Functional Configuration Table
Classify | Function Name | 84(2)1 | 822 | 842 | 84(2)3 |
Protection Function | Sent velocity broken | √ | | | |
Percentage differential protection(secondary harmonic restraint) | √ | | | |
TA disconnexion blocking percentage differential protection | √ | | | |
The differential current limit alarm | √ | | | |
Compound voltage blocking Two sections of three time overcurrent protection | | √ | √ | √ |
Overcurrent inverse time lag | | √ | √ | √ |
Negative sequence over current | | √ | √ | √ |
Overload | | √ | √ | √ |
Overload blocking voltage regulation | | √ | √ | √ |
Overload start air-cooled | | √ | √ | √ |
Proper signal | | √ | √ | |
Transformer tap position and on-load voltage regulation | √ | | | |
Zero-sequence voltage protection | | √ | √ | √ |
A three zero-sequence current protection | | √ | | |
Composite voltage components | | √ | √ | √ |
TV disconnection detect | | √ | √ | √ |
Operation circuit | Power independent containing anti adjustable locking function operation circuit | | √ | √ | √ |
Control circuit abnormal alarm | | √ | √ | √ |
Measurement And Control Function | 16 way remote signal input, device remote signal shift, accident remote signal | √ | √ | √ | √ |
Normal circuit break remote deciliter | √ | √ | √ | √ |
P, Q, IA, IB, IC, Ua, Ub, Uc, COSΦ, f | | √ | √ | √ |
Switch accident in statistics and event SOE etc | √ | √ | √ | √ |
Fault recorder | √ | √ | √ | √ |
Time hack | Realize GPS time hack,network time hack | √ | √ | √ | √ |
Communication | Ethernet, RS232/485 communication interface | √ | √ | √ | √ |
Main Features
a. 4U standard aluminum chassis, combination of plug-in structure, after the plug case,
each functional module design alone, electricity are completely separated, strong anti-interference ability, convenient field maintenance;
b. CPU intelligent card design, open into the open plug-ins to achieve real-time complete self-test; can be detected in each relay coil;
c. Plug-in based on CANBUS bus links between, reduce the connection between the connector plug,
bad real time detection;
d. Double 32 computer systems, the redundant system; protection function using the Dezhou Instrument Company produced the 32 bit floating-point DSP processor, program and data in the
chip operation; operation speed, high reliability;
e. Man-machine interface, network communication and other management functions
by Philips Company produced 32 ARM MCU, speed, on-chip memory capacity big,
strong ability of network interface;
f. 16 AD sampling, high measuring precision; weekly wave 48 sampling points, harmonic processing capability;
g. Protection module using computer assisted graphical interface design is convenient for the two series of products development and functional modifications, flexible, efficient engineering design;
h. Complete the circuit breaker control circuit is provided with a remote control, jump, closing, spring without stored energy blocking close function etc;
i. Use 192*64 monochrome graphic LCD, Chinese menu interface; the flexibility to choose double Ethernet and double 485 interface;
j. Can save at least 500 report recent incidents and operation report;
k. User management module using real-time multitask operating system, network interface, tasks such as real-time;
l. Can store 10 sets of protection setting value, double value zone self-test and mutual combination,
setting change safely and convenient.
m. Based on electric power industry standard DL / T667-1999 (IEC 60870-5-103) standard
communication protocol, and convenient with microcomputer monitoring or protect management computer network communication.3. Technical Index3.1 Rated Data
a. Rated DC voltage: 220V (110V orders indicate) allowable deviation +15%,-20%
Rated AC data: phase voltage 100/√3V
Zero-sequence voltage 100V
AC current 5A (1A orders indicate)
Rated frequency 50Hz (60Hz orders indicate)
b. Thermal Stability:
AC voltage circuit: long time operation 1.4Un
AC current circuit: long time operation 2In
10s 20In
1s 40In3.2 Consumptiona. AC voltage circuit: phase≤0.5VA;
b. AC current circuit: when In=5A ,phase ≤1VA;when In=1A, phase≤0.5VA;
c. Protection power supply circuit: when in normal work, ≤10W; in protection action, ≤15W.3.3 Environment Conditiona. Environment temperature:
Work: -25ºC~+55ºC
Storage: -25ºC~+70ºC,Relative humidity of not more than 80%, the ambient air does not contain acidic, alkaline or other corrosive and explosive gases prevent rain, snow indoor; the limit without applying excitation volume, device is not irreversible change in appearance, temperature after recovery, device can work normally.
b. Relative humidity: Most of the wet mean monthly maximum relative humidity is 90%, and the monthly mean minimum temperature is 25ºC and the surface without gel. When the maximum temperature is +40ºC, the average maximum humidity is not more than 50%.
c. Atmospheric pressure:80kPa~110kPa(Altitude < 2km).3.4 Anti-interference Performancea. Burst Disturbance: GB/T14598.13 - 1998 1MHz 100kHz ( 2.5kV , 1kV ).Bur Test: acceptable burst disturbance tests of 1MHz and 100 kHz damped oscillation waves (first half-wave voltage
amplitude common-mode is 2.5kV and differential mode is 1kV) in GB/T14598.13 - 1998.
b. Fast Transient Disturbance Test: acceptable fast transient disturbance test whose severity level is IV in Chapter 4, GB/T14598.10 - 1997.
c. Radiated Electromagnetic Field Disturbance Test: accept radiated electromagnetic field disturbance test whose severity level is III in Chapter 4, GB/T14598.9 - 2002.
d. Electrostatic Discharge Test: acceptable electrostatic discharge test whose severity level is IV in Chapter 4, GB/T14598.14 - 1998.
e. Electromagnetic Emission Test: acceptable GB/T14598.16 - 2002 Conducted emission requirements in 4.1 and 4.2 limits the provisions of the electromagnetic radiation emission limits for emission tests.
f. Power : GB/T17626.8 - 1998 5 IV .Frequency Magnetic Field Immunity Test: acceptable power frequency magnetic field immunity tests whose severity level is IV in Chapter 5, GB/T17626.8- 1998.
g. Pulse Magnetic Field Immunity Test: acceptable pulse magnetic field immunity tests whose severity level is IV in Chapter 5, GB/T17626.9 - 1998.
h. Damped oscillatory magnetic field immunity test: accept damp oscillatory magnetic field immunity test whose severity level is IV in Chapter 5, GB/T17626.9 - 1998.
i. Surge Immunity Test: acceptable surge immunity tests whose severity level is IV in Chapter 4, IEC 60255-22-5: 2002.
j. Immunity to Conducted Disturbances Test: acceptable immunity to conducted disturbances test, induced by radio-frequency field in Chapter 4, IEC 60255-22-6: 2001
k. Power : IEC 60255-22-7 : 2003 4 .Frequency Immunity Test: acceptable power frequency
immunity tests in Chapter 4, IEC 60255-22-7: 2003.
Address:
A4 Building, Lugu International Industrial Park, No. 229, Tongzipo West Road, High-Tech Development Zone, Changsha, Hunan, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 9000
Company Introduction:
Changsha Guotong Electrical Technology Co. Ltd. Is a specialized corporate integrated R&AMP;D, design, production and sales of microcomputer protection and integrated automation systems fitting for hydropower, power, pump and thermal power stations etc.
As a rapid developing corporation, Guotong has been optimizing its products. Nowadays, GT8000 series has been attached most importance, which can be applied to transformer substation, hydropower station, switch station, pumping station, power plant, cement factories, railway, chemical, environmental protection, steel, coal and mine substation etc. Of 110kv and below. Moreover, Guotong Electric successfully constructed multi-level marketing networks around domestic and abroad, which is covered a number of countries and regions, such as the Middle East, East Europe, South Africa, Southeast Asia, and South America.
Guotong adheres to the spirit of market oriented and innovation as strength and keep technological leadership, transforming science and technology into reality. Therefore, Guotong has received a number of related intellectual property rights and internationally recognized.